Code | Description |
100-xxx | Batch controller Batching Master 110 (i) / 210 (i) |
Order Code: | Product Description: |
100-0110 | Batching Master 110i |
Intrinsically safe field housing device, IP65, ATEX | |
100-0120 | Batching Master 110 |
Non-Ex, field housing IP65 | |
100-0130 | Batching Master 210i |
Intrinsically safe panel mount device, ATEX | |
100-0140 | Batching Master 210 |
Non-Ex, panel mount device | |
100-0145 | Backlight for the LCD |
This option requires an additional power supply module PSC 300i for | |
intrinsically safe devices | |
100-0150 | Modbus interface |
TTY at intrinsically safe devices, RS485 at non-Ex devices | |
This option requires an IPC 300i module for intrinsically safe devices | |
100-0160 | Terminal function |
This price includes the price for the option Modbus interface | |
100-0165 | Custody transfer version |
This price includes the price for the option Modbus interface | |
100-0170 | PID controller function |
100-0175 | Flow correction function |
Calculation between mass flow, volume flow and volume flow at | |
standard temperature | |
120-0180 | Automatic purge function “Filling and Emptying” |
Special software function | |
Function keys F1-F3 | |
100-0191 | 3 product ways |
100-0192 | 3 fixed pre-selections |
100-0193 | 3 fixed controller set points |
100-0200 | Emergency stop as a key switch |
only for field housing devices available | |
Accessories / Interface Cards: | |
A-100-0210 | Intrinsically safe power supply module |
PSC 300i, 1-channel | |
DIN rail housing, 24V power supply | |
A-100-0220 | Interface and power supply module IPC 300i |
DIN rail housing, 24V power supply | |
- interface barrier between intrinsically safe and RS485, non-Ex | |
- one intrinsically safe power supply output | |
200-xxx | Exi PID controller CTR 210i |
Order Code: | Product Description: |
200-0110 | CTR 210i |
Intrinsically safe panel mount device, ATEX approval | |
200-0130 | Pt100 temperature input |
Price for each analogue input as Pt100 (3-wire) | |
200-0150 | Modbus interface |
This option requires an IPC 300i interface module | |
Software Functions: | |
200-0160 | Cascade controller function |
220-0170 | Automatic setpoint ramp function |
With 16 steps | |
200-0180 | Double loop controller software |
200-0190 | Manual / Automatic station |
Special software | |
200-0200 | Setpoint station |
Special software | |
Accessories / Interface Cards: | |
A-200-0210 | Field housing |
IP65 | |
A-200-0220 | Intrinsically safe power supply module |
PSC 300i, 1-channel | |
DIN rail housing, 24V power supply | |
A-200-0230 | Intrinsically safe power supply module |
PSC 300i, 2-channel | |
DIN rail housing, 24V power supply | |
Channel one for the first power supply of the CTR 210i | |
Channel two only for the second power supply of the CTR 210i | |
A-200-0240 | Interface and power supply module IPC 300i |
DIN rail housing, 24V power supply | |
- interface barrier between intrinsically safe and RS485, non-Ex | |
- one intrinsically safe power supply output | |
300-xxx | Exi Bargraph indicator BGI 210 (i) |
Order Code: | Product Description: |
300-0110 | BGI 210i |
Intrinsically safe panel mount device, ATEX approval | |
300-0130 | Pt100 temperature input |
Price for each analogue input as Pt-100 (3-wire) | |
300-0150 | Modbus interface |
This option requires an IPC 300i interface module | |
Accessories / Interface Cards: | |
A-300-0160 | Field housing |
IP65 | |
A-300-0170 | Intrinsically safe power supply module |
PSC 300i, 1-channel | |
DIN rail housing, 24V power supply | |
A-300-0180 | Intrinsically safe power supply module |
PSC 300i, 2-channel | |
DIN rail housing, 24V power supply | |
Channel one for the first power supply of the BGI 210i | |
Channel two only for the second power supply of the BGI 210i | |
A-300-0190 | Interface and power supply module IPC 300i |
DIN rail housing, 24V power supply | |
- interface barrier between intrinsically safe and RS485, non-Ex | |
- one intrinsically safe power supply output | |
400-xxx | Exi Recorder ExTrend 200i |
Order Code: | Product Description: |
400-0110 | ExTrend 200i, 6-channel |
Intrinsically safe chart recorder in panel mount housing | |
Power supply via IPM 300i interface module (see A-400-0150) | |
6 x analogue inputs Pt100 or 4-20 mA, passive | |
6 x digital inputs, active | |
6 x digital outputs, passive | |
Intrinsically safe interface with Modbus protocol | |
400-0120 | ExTrend 200i, 3-channel |
Intrinsically safe chart recorder in panel mount housing | |
Power supply via IPM 300i interface module (see A-400-0150) | |
3 x analogue inputs Pt100 or 4-20 mA, passive | |
6 x digital inputs, active | |
6 x digital outputs, passive | |
Intrinsically safe interface with Modbus protocol | |
Accessories / Interface Cards: | |
A-400-0150 | Interface and power supply module IPM 300i |
DIN rail housing, 24V power supply | |
- interface barrier between intrinsically safe and RS485, non-Ex | |
- two intrinsically safe power supply outputs | |
500-xxx | Batch controller BC 20 |
Order Code: | Product Description: |
500-0110 | BC 20 - DC |
Panel mount housing 96 x 96 x 120 mm | |
LC-display with backlight, 2 x 16 characters, 5,6 mm height | |
Power supply 24 VDC | |
3 x analogue input, 4-20 mA, passive | |
1 x pulse input, active | |
3 x digital input, active | |
2 x optocoupler output, passive, Imax = 50 mA | |
2 x relay output, passive change-over contact, Imax= 3A, Umax= 250V | |
1 x valve output signal, 4-20 mA, active, optional | |
(see 500-0130 or 500-0140) | |
1 x RS485 interface with Modbus protocol, optional | |
(see 500-0150) | |
500-0120 | BC 20 - AC |
Panel mount housing 96 x 96 x 120 mm | |
LC-display with backlight, 2 x 16 characters, 5,6 mm height | |
Power supply 85-240 VAC, 47-63Hz | |
3 x analogue input, 4-20 mA, passive | |
1 x pulse input, active | |
3 x digital input, active | |
2 x optocoupler output, passive, Imax = 50 mA | |
2 x relay output, passive change-over contact, Imax= 3A, Umax= 250V | |
1 x valve output signal, 4-20 mA, active, optional | |
(see 500-0130 or 500-0140) | |
1 x RS485 interface, Modbus protocol, optional | |
(see 500-0150) | |
500-0130 | Valve output signal 4-20 mA, active |
With a start-up ramp and a 5-step shut-off ramp | |
500-0140 | Valve output signal with PID flow control function |
PID control function for the flow rate control during the batch. | |
Price includes 500-0130 | |
500-0150 | RS485 interface with Modbus protocol |
600-xxx | Flow computer Pipeline Master 110 (i) / 210 (i) |
Order Code: | Product Description: |
600-0110 | Pipeline Master 110i |
Intrinsically safe field housing device, IP65, ATEX approval | |
600-0120 | Pipeline Master 110 |
Non-Ex, field housing IP65 | |
600-0130 | Pipeline Master 210i |
Intrinsically safe panel mount device, ATEX approval | |
600-0140 | Pipeline Master 210 |
Non-Ex, panel mount device | |
600-0145 | Back light for the LCD |
This option requires an additional power supply module PSC 300i for | |
intrinsically safe devices | |
600-0150 | Modbus interface |
TTY at intrinsically safe devices, RS485 at non-Ex devices | |
This option requires an IPC 300i module for intrinsically safe devices | |
600-0160 | Terminal function |
This price includes the price for the option Modbus interface | |
600-0165 | Custody transfer version |
This price includes the price for the option Modbus interface | |
600-0175 | Flow correction function |
Calculation between mass flow, volume flow and volume flow at | |
standard temperature | |
Accessories / Interface Cards: | |
A-600-0210 | Intrinsically safe power supply module |
PSC 300i, 1-channel | |
DIN rail housing, 24V power supply | |
A-600-0220 | Interface and power supply module IPC 300i |
DIN rail housing, 24V power supply | |
- interface barrier between intrinsically safe and RS485, non-Ex | |
- one intrinsically safe power supply output | |
700-xxx | PCC 400 Printer control system |
with data storage function | |
Order Code: | Product Description: |
PCC 400 for the Batching Master: | |
700-0110 | PCC 400 for 1-8 Batching Masters |
One additional interface module EX9520R is required. | |
700-0120 | PCC 400 for 1-16 Batching Masters |
One additional interface module EX9520R is required. | |
Optional software functions for 700-0110 and 700-0120: | |
700-0130 | Terminalfunktion for the input of max. 10 information before |
the batch start | |
700-0131 | Selection of 7 product ways |
The product ways will be switched via the Modbus relay | |
module EX90670D-M. (Price see A-700-0320) | |
700-0132 | Automatic writing function into an external MySQL data |
base | |
PCC 400 für Pipeline Master: | |
700-0210 | PCC 400 for 1-8 Pipeline Masters |
One additional interface module EX9520R is required. | |
700-0210 | PCC 400 for 1-16 Pipeline Masters |
One additional interface module EX9520R is required. | |
Accessories / Interface Cards: | |
A-700-0310 | Interface converter EX9520R from RS232 to RS485 |
A-700-0320 | Modbus relay module EX9067D-M |
A-700-0410 | Printer IBS ML 3320 with CT approval incl. serial interface |
Batchcontrol Vietnam | ANS Vietnam