Pressure and Temperature Transmitters

ATM.1ST/T

 

  • Pressure measuring range: 100 mbar…25 bar
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -50…150 °C
  • Operating temperature: -40…125 °C
  • Process temperature: -50…150 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel

ATM.1ST

 

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.10 / 0.05 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: 0…5 / 0…10 V DC, 4…20 mA
  • Total Error Band: ≤ ± 0.30 %FS (0…70 °C)
  • Materials: Stainless steel, Titanium

ATM.1ST/Ex

 

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.10 / 0.05 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: 4…20 mA
  • Total Error Band: ≤ ± 0.30 %FS (0…70 °C)
  • Materials: Stainless steel, Titanium

ATM.ECO

 

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: 0…5 / 0…10 V DC, 4…20 mA
  • Total Error Band: ≤ ± 0.70 %FS (0…70 °C)
  • Materials: Stainless steel, Titanium

ATM.ECO/Ex

 

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: 4…20 mA
  • Total Error Band: ≤ ± 0.70 %FS (0…70 °C)
  • Materials: Stainless steel, Titanium

ATM

 

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Output signal: 0…5 / 0…10 V DC, 0…20 / 4…20 mA
  • Materials: Stainless steel, Titanium

ATM/Ex

 

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium

ATM/F

 

  • Pressure measuring range: 100 mbar…25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -25…100 °C
  • Output signal: 0…5 / 0…10 V DC, 0…20 / 4…20 mA
  • Materials: Stainless steel

ATM/F/Ex

 

  • Pressure measuring range: 100 mbar…25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -25…100 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel

ATM/GR

 

  • Pressure measuring range: 100 mbar…1000 bar
  • Two potential free switches (48 V, 2 A, 60W)
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Materials: Stainless steel, Titanium
  • Feature: Output signal 0…20 mA / 4…20 mA

ATM/K

 

  • Pressure measuring range: 100 mbar…25 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…125 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel

ATM/T

 

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Temperature measuring range: -50…150 °C
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • 2 Output signals (p & T): 0…10 V DC, 0…20 / 4…20 mA
  • Materials: Stainless steel, Titanium

DTM

 

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Interface: RS232, RS485
  • Materials: Stainless steel, Titanium

PTM

 

  • Pressure measuring range: 100 mbar…1000 bar
  • Adjustable: 1:4 of the nominal range within -5% to +105%
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible

PTM/Ex

 

  • Pressure measuring range: 100 mbar…1000 bar
  • Adjustable 1:4 of the nominal range within -5% to +105%
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible

PTM/RS485

 

  • Pressure measuring range: 100 mbar…1000 bar
  • Adjustable 1:4 of the nominal range within -5% to +105% (analog output)
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -25…85 °C
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • 2 Output signals (p & T): 4…20 mA
  • Interface: RS485 (Modbus RTU)
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible

TM

 

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: mV
  • Materials: Stainless steel, Titanium

TM/Ex

 

  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: mV
  • Materials: Stainless steel, Titanium

TS 100

 

  • Temperature measuring range: -50…150 °C
  • Operating temperature: -25…85 °C
  • Process temperature: -50…150 °C
  • Output signal: 0…5 / 0…10 V DC, 0…20 / 4…20 mA
  • Materials: Stainless steel
  • Feature: 850 bar proof pressure


Datasheet

 

STS Sensor Vietnam | ANS Vietnam