				 In 1988, DOLD developed their first emergency stop module BN 5983 for man-machine protection. Conventional contactor controls with their expensive interconnection wiring could be replaced with this product and a lot of space could be saved in the control cabinet. With current emergency stop modules featuring a width of only 17.5 mm and a depth of only 70 mm, DOLD has again set new standards for safety relay modules. In large installations with multiple emergency-stop buttons, it is useful to quickly know which emergency-stop button has been operated to minimise downtimes. For this application DOLD offer specific emergency stop button monitors with indication and bus outputs. 
  | 
			
				![]()  | 
		
Advantages
Emergency stop modules
- 
			Safety category up to EN 954, SC4
 - 
			Safe thanks to potential-free contacts
 - 
			Miniaturization space saving designs
 - 
			Gold-plated contacts, for low loads
 - 
			Easy wiring saves cost
 - 
			Tailored to your applications
 - 
			Quick module replacement via detachable terminals
 - 
			Preconfigured type-tested modules save time and cost
 
Emergency stop monitors
- 
			Quick identification of the depressed emergency-stop button via clear LED indication
 - 
			Reduced downtime, due to fast location of the depressed emergency-stop button
 - 
			A choice of signalling to primary controls and displays via bus interface or BCD coded outputs
 - 
			
Emergency stop modules SAFEMASTER ®
					Emergency stop monitors SAFEMASTER®
Emergency stop modules SAFEMASTER ®All products mentioned comply with the safety category 4 acc. to EN 954.Function Also suited as 
safety gate monitorSafety category 
acconting to
EN 954-1 1) Performance Level 
to EN 13849-1 1) SIL Claimed Level 
EN 62061 1)1- channel/ 
2-channel Output contacts, max. Breaking current Ith [A] max. width [mm] Type Emergency stop module with var. Terminals 4 2) 2) 1 4NO 5 A 22.5 LG 5924 Emergency stop module with var. Terminals + 4 e 3 1; 2 4NO 5 A 22.5 LG 5925 Emergency stop module 4 e 3 1 4NO 7 A 22.5; 70 BG 5924, IP 5924 Emergency stop module, most compact design 4 e 3 1 1NO 5 A 17.5 RK 5942 Emergency stop module + 4 2) 2) 1; 2 2NO 10 A 45 BD 5987 Emergency stop module + 4 2) 2) 1; 2 3NO 7 A 22.5 BG 5925 Emergency stop module + 4 2) 2) 1; 2 3NO, 1NC 10 A 100 BN 5983 Emergency stop module + 4 2) 2) 1; 2 3NO, 1NC 10 A 45 BD 5935 Emergency stop module with delay up to 300s + e 3 1;2 2NO, 1NO 
contact
delayed8 A 22.5 LG 5928 
New !Emergency stop module with delay up to 300s + 4 e 3) 1; 2 3NO, 3NO 
contact
delayed5 A 45 BH 5928 Emergency stop module with delay up to 300s + 4 e 3) 1; 2 3NO, 3NO 
contact
delayed5 A 67.5 BI 5928 Emergency stop module 
with power failure detection4 2) 2) 1; 2 3NO 5 A 90 BH 5903 Emergency stop module 
with power failure detection4 2) 2) 1; 2 3NO 5 A 90 BL 5903 Emergency stop module + 4 e 3 1; 2 3NO, 1NC 10 A 100 BN 5930.48/203, 
BN 5930.48/204NO = normally open contact, NC = normally closed contact , NO contact delayedFor multiple monitored emergency-stop buttons in combination with further safety functions see SAFEMASTER®C and SAFEMASTER®M 