Emergency stop modules / monitors

In 1988, DOLD developed their first emergency stop module BN 5983 for man-machine protection. Conventional contactor controls with their expensive interconnection wiring could be replaced with this product and a lot of space could be saved in the control cabinet. With current emergency stop modules featuring a width of only 17.5 mm and a depth of only 70 mm, DOLD has again set new standards for safety relay modules.

In large installations with multiple emergency-stop buttons, it is useful to quickly know which emergency-stop button has been operated to minimise downtimes. For this application DOLD offer specific emergency stop button monitors with indication and bus outputs.

 

xxx

DOLD Not-Aus Modul LG5925

Advantages

Emergency stop modules

  • Safety category up to EN 954, SC4
  • Safe thanks to potential-free contacts
  • Miniaturization space saving designs
  • Gold-plated contacts, for low loads
  • Easy wiring saves cost
  • Tailored to your applications
  • Quick module replacement via detachable terminals
  • Preconfigured type-tested modules save time and cost

 

Emergency stop monitors

  • Quick identification of the depressed emergency-stop button via clear LED indication
  • Reduced downtime, due to fast location of the depressed emergency-stop button
  • A choice of signalling to primary controls and displays via bus interface or BCD coded outputs
  • Emergency stop modules SAFEMASTER ®

    Emergency stop monitors SAFEMASTER®

    Emergency stop modules SAFEMASTER ®
    All products mentioned comply with the safety category 4 acc. to EN 954.
    Function Also suited as
    safety gate monitor
    Safety category
    acconting to
    EN 954-1 1)
    Performance Level
    to EN 13849-1 1)
    SIL Claimed Level
    EN 62061 1)
    1-channel/
    2-channel
    Output contacts, max. Breaking current Ith [A] max. width [mm] Type
                       
    Emergency stop module with var. Terminals   4 2) 2) 1 4NO 5 A 22.5 LG 5924
    Emergency stop module with var. Terminals + 4 e 3 1; 2 4NO 5 A 22.5 LG 5925
    Emergency stop module   4 e 3 1 4NO 7 A 22.5; 70 BG 5924, IP 5924
    Emergency stop module, most compact design   4 e 3 1 1NO 5 A 17.5 RK 5942
    Emergency stop module + 4 2) 2) 1; 2 2NO 10 A 45 BD 5987
    Emergency stop module + 4 2) 2) 1; 2 3NO 7 A 22.5 BG 5925
    Emergency stop module + 4 2) 2) 1; 2 3NO, 1NC 10 A 100 BN 5983
    Emergency stop module + 4 2) 2) 1; 2 3NO, 1NC 10 A 45 BD 5935
    Emergency stop module with delay up to 300s +   e 3 1;2 2NO, 1NO
    contact
    delayed
    8 A 22.5 LG 5928
    New !
    Emergency stop module with delay up to 300s + 4 e 3) 1; 2 3NO, 3NO
    contact
    delayed
    5 A 45 BH 5928
    Emergency stop module with delay up to 300s + 4 e 3) 1; 2 3NO, 3NO
    contact
    delayed
    5 A 67.5 BI 5928
    Emergency stop module
    with power failure detection
      4 2) 2) 1; 2 3NO 5 A 90 BH 5903
    Emergency stop module
    with power failure detection
      4 2) 2) 1; 2 3NO 5 A 90 BL 5903
    Emergency stop module + 4 e 3 1; 2 3NO, 1NC 10 A 100 BN 5930.48/203,
    BN 5930.48/204
    NO = normally open contact, NC = normally closed contact , NO contact delayed
    For multiple monitored emergency-stop buttons in combination with further safety functions see SAFEMASTER®C and SAFEMASTER®M

 

Dold Vietnam | ANS Vietnam