IMR 1000
The IMR 1000 is a hand held pocket size stack gas analyzer for combustion tests on boilers, burners, etc.. The IMR 1000-1/IMR 1000-2 have up to two sensors with a 2-line LCD while the IMR 1000-3/IMR 1000-4 have a 4-line LCD with up to 3 sensors
  • small, rugged and easy to operate
  • up to 3 sensors
  • Memory
  • Light weight
  • Infrared interface for a printer
  • Protective boot with integral magnet
  • Large backlit, display
  • Reliable technology and easy to service
Measured parameters: Calculated parameters:
  • Oxygen O2
  • Carbon monoxide CO
  • Nitric Oxide NO
  • Draft/Pressure
  • Stack gas temperature
  • Combustion efficiency
  • Excess Air
  • Carbon dioxide CO2
  • CO air free (cor. to 0% O2)
  

          IMR-1000


IMR1000-1
IMR1000-2
IMR 1100-1/-2
       IMR1000-3
       IMR1000-4
IMR 1100-3/-4
IMR-1000  

STANDARD
Enclosure:
Rugged plastic case with a protective boot and magnet
Zero point calibration:
Max. 60 seconds
Gas sampling probe
Thermocouple K; dia. 0.25"/6mm; L=9"/220mm; hose length 9'/3m
Fuels:
Natural Gas, Propane, Butane, LPG, Light Oil
Power Supply:
4 x AA-batteries
> 8 hours 
Weight:
2.2lbs/1kg
Measuring units:
ppm, mg/m3
Languages:
English, German, French, etc.
Dimensions:
7.9x1.8x3.5" / 200x45x90mm
Service Program
Check of all values
Condensation trap:
With integrated filter
   

 

IMR Vietnam | ANS Vietnam

TECHNICAL DATA
PARAMETER Resolution 1000-1 1000-2 1000-3 1000-4
O2 Oxygen 0.1% 0-20.9% 0-20.9% 0-20.9% 0-20.9%
CO Carbon monoxide 1ppm   0-1000ppm 0-4000ppm 0-4000ppm
TG Gas temperature 1F/1C 32-1112F 32-1112F 20-2400F 20-2400F
TI Inlet temperature 1F/1C     20-2400F 20-2400F
TA Air temperature 1F/1C     32-112F 32-112F
CO2 Carbon dioxide 0.1% 0-30% 0-30% 0-30% 0-30%
Combustion Efficiency/ ETA 0.1% 0-99.9% 0-99.9% 0-99.9% 0-99.9%
Excess Air / LAMBDA 0.1% 0-250% 0-250% 0-250% 0-250%
CO/CO2 Ratio       0-0.999% 0-0.999%
NO Nitric Oxide 1ppm       0-30ppm
P Pressure       +/- 32"wg +/- 32"wg
Other measuring ranges are available upon request

PARAMETER 1000-1 1000-2 1000-3 1000-4
WORKLIGHT         ü ü
LOW BATTERY INDICATION     ü ü
INDIVIDUAL PRINTOUTS     ü ü
MEMORY   20 179 179
IR-PRINTER PORT ü ü ü ü
BACKLIT DISPLAY 2-lines 2-lines 4-lines 4-lines
BOOT WITH MAGNET ü ü ü ü
USER PROGRAMMABLE HEADER ü ü ü ü
TIME & DATE STAMP ü ü ü ü

OPTIONS / ACCESSORIES PART NO.
AC- adapter 11002-AC
Infrared printer 11002-PR
Gas sampling probe 11002-GASP
Soft carrying case 11002-SCAR
Hard carrying case 11002-HCAR

MODELS PART NO.
IMR 1000-1 O2, condensation trap, batteries, operators manual 10001
IMR 1000-2 O2, CO, condensation trap, batteries, operators manual 10002
IMR 1000-3 O2, CO, draft, condensation trap, batteries, operators manual 10003
IMR 1000-4 O2, CO, NO, draft, condensation trap, batteries, operators manual 10004