IMR 2800-A
Gas analyzer for automotive emissions
Latest sensor technology for a more accurate
measurement and a longer life time
Improved interior design for easier service
and better unit protection
Measures up to 8 gases
Larger display for better reading
Increased memory
Latest NDIR-technology to measure CO, CO2
and HC
Applications: Cars, Trucks, Motorcycles,
Engines, Turbines, Cogeneration plants
IMR-2800-A
|
IMR 2800-Automotive
 |
STANDARD FEATURES |
 |
Portable automotive gas analyzer housed in a rugged aluminum case |
 |
Simultaneous measurement of
O2 Oxygen |
CO2 Carbon dioxide |
CO Carbon Monoxide |
HC Hydrocarbons |
NO Nitric oxide |
TG Flue gas temperature |
TA Ambient air temperature |
|
|
 |
Automatic zero calibration |
 |
Integrated self check program |
 |
Simultaneous display of 8 parameters on the illuminated display |
 |
Thermal printer with programmable print-out cycles |
 |
Standard deviation and average value calculation |
 |
Serial interface RS232 |
 |
Gas sampling probe E – length 0.8 ft (250mm) , hose 8 ft (2.5m) |
 |
Power supply 110VAC/60Hz or 230VAC/50Hz |
|
OPTIONAL FEATURES |
 |
H2S sensor |
 |
Gas sampling probes with different lengths |
|
NO2 sensor |
|
Soot measurement |
 |
SO2 sensor |
 |
Draft measurement |
|
THE ALL NEW AUTOMOTIVE FLUE GAS ANALYZER IMR 2800 - A |
|
TECHNICAL DATA
PARAMETER |
PRINCIPLE |
RESOLUTION |
ACCURACY |
RANGE |
STANDARD |
O2 Oxygen |
Electro-chemical |
0.1 % |
± 0.2 % |
0-25 % |
ü
|
CO Carbon monoxide |
NDIR |
0.01 % |
± 4 % rel. |
0-10 % |
ü
|
NO Nitric oxide |
Electro-chemical |
1 ppm |
± 4 % rel. |
0-5,000 ppm |
ü |
CO2 Carbon dioxide |
NDIR |
0.1 % |
± 4 % rel. |
0-20 % |
ü |
HC Hydrocarbons |
NDIR |
1 ppm |
± 4 % rel. |
0-30,000 ppm |
ü |
SO2 Sulfur dioxide |
Electro-chemical |
1 ppm |
5 % |
0-4,000 ppm |
optional |
NO2 Nitric dioxide |
Electro-chemical |
1 ppm |
5 % |
0-100 ppm |
optional |
H2S Hydrogen sulfide |
Electro-chemical |
1 ppm |
5 % |
0-200 ppm |
optional |
TG Flue gas temperature |
NiCr-Ni thermocouple |
1 K |
± 2 % |
-20°C / 1200°C -4° F / 2192° F |
ü
|
TA Air temperature |
Semiconductor |
1 K |
± 0.5 K |
-20°C / 120°C -4° F / 248° F |
ü |
P Draft |
Solid state |
0.01 hPa
0.004" H2O |
± 2 % |
-20 / 20 hPA
-8" / 8" H2O |
optional |
Soot |
Filter paper method |
|
|
|
optional |
Other measurement ranges are available upon request
Equipped with max. 8 sensors |
SPECIFICATION |
Dimensions wxdxh: 15"(315mm) x 6.5"(185mm) x 12.4"(380mm) |
Weight: approx. 17lbs. (8kg) |
MODEL |
PART-NO. |
IMR 2800-A O2, CO, CO2, NO,HC |
28100 |
|
|
IMR Vietnam | ANS Vietnam